{"id":13363,"date":"2023-02-27T08:46:57","date_gmt":"2023-02-27T08:46:57","guid":{"rendered":"https:\/\/www.gph.lt\/?post_type=product&#038;p=13363"},"modified":"2023-03-21T08:48:39","modified_gmt":"2023-03-21T08:48:39","slug":"12-kv-class-2-outdoor-type-surge-arresters","status":"publish","type":"product","link":"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/","title":{"rendered":"12 kV Class 2 outdoor type surge arresters"},"content":{"rendered":"<p><strong>OCP2-12<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<th width=\"256\">Housing parameters<\/th>\n<th width=\"256\">Measuring units<\/th>\n<th width=\"256\">S<\/th>\n<th width=\"256\">L<\/th>\n<\/tr>\n<tr>\n<td width=\"256\">Impulse voltage 1,2\/50 \u00b5s<\/td>\n<td width=\"256\">kV<\/td>\n<td width=\"256\">145<\/td>\n<td width=\"256\">165<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Industrial frequency voltage<\/td>\n<td width=\"256\">kV<\/td>\n<td width=\"256\">47<\/td>\n<td width=\"256\">57<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Height (H)<\/td>\n<td width=\"256\">mm<\/td>\n<td width=\"256\">183<\/td>\n<td width=\"256\">220<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Overlap distance<\/td>\n<td width=\"256\">mm<\/td>\n<td width=\"256\">176<\/td>\n<td width=\"256\">214<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Leakage path length<\/td>\n<td width=\"256\">mm<\/td>\n<td width=\"256\">380<\/td>\n<td width=\"256\">505<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Weight<\/td>\n<td width=\"256\">kg<\/td>\n<td width=\"256\">1,8<\/td>\n<td width=\"256\">2,2<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Number of skirts<\/td>\n<td width=\"256\"><\/td>\n<td width=\"256\">5<\/td>\n<td width=\"256\">7<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Bending resistance*<\/td>\n<td width=\"256\">Nm<\/td>\n<td width=\"256\">350<\/td>\n<td width=\"256\">350<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Resistance to pulling<\/td>\n<td width=\"256\">N<\/td>\n<td width=\"256\">2000<\/td>\n<td width=\"256\">2000<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Max. torque M12*<\/td>\n<td width=\"256\">Nm<\/td>\n<td width=\"256\">50<\/td>\n<td width=\"256\">50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>* Based on &#8220;Thermomechanical and bending moment test IEC 60099-4&#8221;<\/em><\/p>\n<table>\n<tbody>\n<tr>\n<th colspan=\"6\" width=\"1026\">Residual voltage (kV)<\/th>\n<\/tr>\n<tr>\n<th colspan=\"3\" width=\"513\">Lightning current pulse 8\/20 \u00b5s:<\/th>\n<th width=\"171\">Steady lightning current pulse 1\/20 \u00b5s:<\/th>\n<th colspan=\"2\" width=\"342\">Switching current pulse 30\/60 \u00b5s:<\/th>\n<\/tr>\n<tr>\n<td width=\"171\">5 kA<\/td>\n<td width=\"171\">10 kA<\/td>\n<td width=\"171\">20 kA<\/td>\n<td width=\"171\">10 kA<\/td>\n<td width=\"171\">125 A<\/td>\n<td width=\"171\">500A<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">36,7<\/td>\n<td width=\"171\">38,0<\/td>\n<td width=\"171\">43,4<\/td>\n<td width=\"171\">40,4<\/td>\n<td width=\"171\">29,5<\/td>\n<td width=\"171\">31,1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>OCP2-12 Housing parameters Measuring units S L Impulse voltage 1,2\/50 \u00b5s kV 145 165 Industrial frequency voltage kV 47 57 Height (H) mm 183 220 Overlap distance mm 176 214 Leakage path length mm 380 505 Weight kg 1,8 2,2 Number of skirts 5 7 Bending resistance* Nm 350 350 Resistance to pulling N 2000 [&hellip;]<\/p>\n","protected":false},"featured_media":13364,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[418],"product_tag":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>12 kV Class 2 outdoor type surge arresters - GPH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"12 kV Class 2 outdoor type surge arresters - GPH\" \/>\n<meta property=\"og:description\" content=\"OCP2-12 Housing parameters Measuring units S L Impulse voltage 1,2\/50 \u00b5s kV 145 165 Industrial frequency voltage kV 47 57 Height (H) mm 183 220 Overlap distance mm 176 214 Leakage path length mm 380 505 Weight kg 1,8 2,2 Number of skirts 5 7 Bending resistance* Nm 350 350 Resistance to pulling N 2000 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/\" \/>\n<meta property=\"og:site_name\" content=\"GPH\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-21T08:48:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gph.lt\/wp-content\/uploads\/2023\/02\/ocp2-12.png\" \/>\n\t<meta property=\"og:image:width\" content=\"467\" \/>\n\t<meta property=\"og:image:height\" content=\"553\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/\",\"url\":\"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/\",\"name\":\"12 kV Class 2 outdoor type surge arresters - GPH\",\"isPartOf\":{\"@id\":\"https:\/\/www.gph.lt\/#website\"},\"datePublished\":\"2023-02-27T08:46:57+00:00\",\"dateModified\":\"2023-03-21T08:48:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gph.lt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.gph.lt\/en\/prekes\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Low and medium voltage surge arresters\",\"item\":\"https:\/\/www.gph.lt\/en\/produkto-kategorija\/low-and-medium-voltage-surge-arresters\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"12 kV Class 2 outdoor type surge arresters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gph.lt\/#website\",\"url\":\"https:\/\/www.gph.lt\/\",\"name\":\"GPH\",\"description\":\"a Nexans company\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gph.lt\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"12 kV Class 2 outdoor type surge arresters - GPH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/","og_locale":"en_US","og_type":"article","og_title":"12 kV Class 2 outdoor type surge arresters - GPH","og_description":"OCP2-12 Housing parameters Measuring units S L Impulse voltage 1,2\/50 \u00b5s kV 145 165 Industrial frequency voltage kV 47 57 Height (H) mm 183 220 Overlap distance mm 176 214 Leakage path length mm 380 505 Weight kg 1,8 2,2 Number of skirts 5 7 Bending resistance* Nm 350 350 Resistance to pulling N 2000 [&hellip;]","og_url":"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/","og_site_name":"GPH","article_modified_time":"2023-03-21T08:48:39+00:00","og_image":[{"width":467,"height":553,"url":"https:\/\/www.gph.lt\/wp-content\/uploads\/2023\/02\/ocp2-12.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/","url":"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/","name":"12 kV Class 2 outdoor type surge arresters - GPH","isPartOf":{"@id":"https:\/\/www.gph.lt\/#website"},"datePublished":"2023-02-27T08:46:57+00:00","dateModified":"2023-03-21T08:48:39+00:00","breadcrumb":{"@id":"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.gph.lt\/en\/product\/12-kv-class-2-outdoor-type-surge-arresters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gph.lt\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.gph.lt\/en\/prekes\/"},{"@type":"ListItem","position":3,"name":"Low and medium voltage surge arresters","item":"https:\/\/www.gph.lt\/en\/produkto-kategorija\/low-and-medium-voltage-surge-arresters\/"},{"@type":"ListItem","position":4,"name":"12 kV Class 2 outdoor type surge arresters"}]},{"@type":"WebSite","@id":"https:\/\/www.gph.lt\/#website","url":"https:\/\/www.gph.lt\/","name":"GPH","description":"a Nexans company","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gph.lt\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product\/13363"}],"collection":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/comments?post=13363"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/media\/13364"}],"wp:attachment":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/media?parent=13363"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product_cat?post=13363"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product_tag?post=13363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}