{"id":13193,"date":"2023-02-21T08:46:51","date_gmt":"2023-02-21T08:46:51","guid":{"rendered":"https:\/\/www.gph.lt\/?post_type=product&#038;p=13193"},"modified":"2023-03-15T08:26:33","modified_gmt":"2023-03-15T08:26:33","slug":"compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1","status":"publish","type":"product","link":"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/","title":{"rendered":"Compression tubes for lines without longitudinal load, DIN 46267, Part 1"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<th>Name<\/th>\n<th>Conductor cross-section, mm\u00b2<\/th>\n<th>Conductor \u00d8, mm according to VDE 0295 (L. \u00d8 according to DIN 48201\/1 re\/rm)<\/th>\n<th>Matrix code<\/th>\n<th>D, mm<\/th>\n<th>d, mm<\/th>\n<th>l, mm<\/th>\n<th>Number of clamping points (mech.)<\/th>\n<th>Number of clamping points (hidr.)<\/th>\n<\/tr>\n<tr class=\"odd\">\n<td>6 KU-ZE-V<\/td>\n<td>6<\/td>\n<td>(2.75\/3.2)<\/td>\n<td>5<\/td>\n<td>5.5<\/td>\n<td>3.8<\/td>\n<td>30<\/td>\n<td>2-2<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>10 KU-ZE-V<\/td>\n<td>10<\/td>\n<td>(3.55\/4.1)<\/td>\n<td>6<\/td>\n<td>6.0<\/td>\n<td>4.4<\/td>\n<td>30<\/td>\n<td>2-2<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>16 KU-ZE-V<\/td>\n<td>16<\/td>\n<td>(4.5\/5.1)<\/td>\n<td>8<\/td>\n<td>8.5<\/td>\n<td>5.5<\/td>\n<td>50<\/td>\n<td>2-2<\/td>\n<td>1-1<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>25 KU-ZE-V<\/td>\n<td>25<\/td>\n<td>5.6-6.5(-\/6.3)<\/td>\n<td>10<\/td>\n<td>10.0<\/td>\n<td>7.0<\/td>\n<td>50<\/td>\n<td>2-2<\/td>\n<td>1-1<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>35 KU-ZE-V<\/td>\n<td>35<\/td>\n<td>6.6-7.5(-\/7.5)<\/td>\n<td>12<\/td>\n<td>12.5<\/td>\n<td>8.2<\/td>\n<td>50<\/td>\n<td>2-2<\/td>\n<td>1-1<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>50 KU-ZE-V<\/td>\n<td>50<\/td>\n<td>7.7-8.6(-\/9.0)<\/td>\n<td>14<\/td>\n<td>14.5<\/td>\n<td>10.0<\/td>\n<td>56<\/td>\n<td>3-3<\/td>\n<td>1-1<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>70 KU-ZE-V<\/td>\n<td>70<\/td>\n<td>9.3-10.2(-\/10.5)<\/td>\n<td>16<\/td>\n<td>16.5<\/td>\n<td>11.5<\/td>\n<td>56<\/td>\n<td>3-3<\/td>\n<td>1-1<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>95 KU-ZE-V<\/td>\n<td>95<\/td>\n<td>11.0-12.0(-\/12.5)<\/td>\n<td>18<\/td>\n<td>19.0<\/td>\n<td>13.5<\/td>\n<td>70<\/td>\n<td>4-4<\/td>\n<td>2-2<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>120 KU-ZE-V<\/td>\n<td>120<\/td>\n<td>12.5-13.5(-\/14.0)<\/td>\n<td>20<\/td>\n<td>21.0<\/td>\n<td>15.5<\/td>\n<td>70<\/td>\n<td>4-4<\/td>\n<td>2-2<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>150 KU-ZE-V<\/td>\n<td>150<\/td>\n<td>13.9-15.0(-\/15.8)<\/td>\n<td>22<\/td>\n<td>23.5<\/td>\n<td>17.0<\/td>\n<td>80<\/td>\n<td>4-4<\/td>\n<td>2-2<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>185 KU-ZE-V<\/td>\n<td>185<\/td>\n<td>15.5-16.8(-\/17.5)<\/td>\n<td>25<\/td>\n<td>25.5<\/td>\n<td>19.0<\/td>\n<td>85<\/td>\n<td>4-4<\/td>\n<td>2-2<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>240 KU-ZE-V<\/td>\n<td>240<\/td>\n<td>17.8-19.2(-\/20.3)<\/td>\n<td>28<\/td>\n<td>29.0<\/td>\n<td>21.5<\/td>\n<td>90<\/td>\n<td>5-5<\/td>\n<td>2-2<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>300 KU-ZE-V<\/td>\n<td>300<\/td>\n<td>20.0-21.6(-\/22.5)<\/td>\n<td>32<\/td>\n<td>32.0<\/td>\n<td>24.5<\/td>\n<td>100<\/td>\n<td>\u2013<\/td>\n<td>2-2<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>400 KU-ZE-V<\/td>\n<td>400<\/td>\n<td>22.9-24.6<\/td>\n<td>38<\/td>\n<td>38.5<\/td>\n<td>26.0<\/td>\n<td>150<\/td>\n<td>\u2013<\/td>\n<td>3-3<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>500 KU-ZE-V<\/td>\n<td>500<\/td>\n<td>25.7-27.6<\/td>\n<td>42<\/td>\n<td>42.0<\/td>\n<td>29.0<\/td>\n<td>160<\/td>\n<td>\u2013<\/td>\n<td>3-3<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>625 KU-ZE-V<\/td>\n<td>625<\/td>\n<td>(-\/32.6)<\/td>\n<td>44<\/td>\n<td>44.0<\/td>\n<td>34.5<\/td>\n<td>160<\/td>\n<td>3-3<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Conductors with a sectoral profile must be rounded before pressing. Non-DIN tubing can also be ordered: 400 KU-ZE-S(-V), 500 KU-ZE-S(-V). These products must only be used for compacted Cu conductors. Other sizes are available on request.<\/em><br \/>\n<em>Designations used: rm-round multi-wire; sm-sector multi-wire; re-uniform round monolith; se-uniform sector monolith.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Name Conductor cross-section, mm\u00b2 Conductor \u00d8, mm according to VDE 0295 (L. \u00d8 according to DIN 48201\/1 re\/rm) Matrix code D, mm d, mm l, mm Number of clamping points (mech.) Number of clamping points (hidr.) 6 KU-ZE-V 6 (2.75\/3.2) 5 5.5 3.8 30 2-2 \u2013 10 KU-ZE-V 10 (3.55\/4.1) 6 6.0 4.4 30 2-2 [&hellip;]<\/p>\n","protected":false},"featured_media":13194,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[400],"product_tag":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Compression tubes for lines without longitudinal load, DIN 46267, Part 1 - GPH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Compression tubes for lines without longitudinal load, DIN 46267, Part 1 - GPH\" \/>\n<meta property=\"og:description\" content=\"Name Conductor cross-section, mm\u00b2 Conductor \u00d8, mm according to VDE 0295 (L. \u00d8 according to DIN 48201\/1 re\/rm) Matrix code D, mm d, mm l, mm Number of clamping points (mech.) Number of clamping points (hidr.) 6 KU-ZE-V 6 (2.75\/3.2) 5 5.5 3.8 30 2-2 \u2013 10 KU-ZE-V 10 (3.55\/4.1) 6 6.0 4.4 30 2-2 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/\" \/>\n<meta property=\"og:site_name\" content=\"GPH\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-15T08:26:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gph.lt\/wp-content\/uploads\/2023\/02\/ku-ze-v.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"230\" \/>\n\t<meta property=\"og:image:height\" content=\"186\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/\",\"url\":\"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/\",\"name\":\"Compression tubes for lines without longitudinal load, DIN 46267, Part 1 - GPH\",\"isPartOf\":{\"@id\":\"https:\/\/www.gph.lt\/#website\"},\"datePublished\":\"2023-02-21T08:46:51+00:00\",\"dateModified\":\"2023-03-15T08:26:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gph.lt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.gph.lt\/en\/prekes\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Contact fittings for electrical networks\",\"item\":\"https:\/\/www.gph.lt\/en\/produkto-kategorija\/contact-fittings-for-electrical-networks\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Connectors\",\"item\":\"https:\/\/www.gph.lt\/en\/produkto-kategorija\/contact-fittings-for-electrical-networks\/connectors\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Pressed electrical cables\",\"item\":\"https:\/\/www.gph.lt\/en\/produkto-kategorija\/contact-fittings-for-electrical-networks\/connectors\/pressed-electrical-cables\/\"},{\"@type\":\"ListItem\",\"position\":6,\"name\":\"Compression tubes for lines without longitudinal load, DIN 46267, Part 1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gph.lt\/#website\",\"url\":\"https:\/\/www.gph.lt\/\",\"name\":\"GPH\",\"description\":\"a Nexans company\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gph.lt\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Compression tubes for lines without longitudinal load, DIN 46267, Part 1 - GPH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/","og_locale":"en_US","og_type":"article","og_title":"Compression tubes for lines without longitudinal load, DIN 46267, Part 1 - GPH","og_description":"Name Conductor cross-section, mm\u00b2 Conductor \u00d8, mm according to VDE 0295 (L. \u00d8 according to DIN 48201\/1 re\/rm) Matrix code D, mm d, mm l, mm Number of clamping points (mech.) Number of clamping points (hidr.) 6 KU-ZE-V 6 (2.75\/3.2) 5 5.5 3.8 30 2-2 \u2013 10 KU-ZE-V 10 (3.55\/4.1) 6 6.0 4.4 30 2-2 [&hellip;]","og_url":"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/","og_site_name":"GPH","article_modified_time":"2023-03-15T08:26:33+00:00","og_image":[{"width":230,"height":186,"url":"https:\/\/www.gph.lt\/wp-content\/uploads\/2023\/02\/ku-ze-v.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/","url":"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/","name":"Compression tubes for lines without longitudinal load, DIN 46267, Part 1 - GPH","isPartOf":{"@id":"https:\/\/www.gph.lt\/#website"},"datePublished":"2023-02-21T08:46:51+00:00","dateModified":"2023-03-15T08:26:33+00:00","breadcrumb":{"@id":"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.gph.lt\/en\/product\/compression-tubes-for-lines-without-longitudinal-load-din-46267-part-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gph.lt\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.gph.lt\/en\/prekes\/"},{"@type":"ListItem","position":3,"name":"Contact fittings for electrical networks","item":"https:\/\/www.gph.lt\/en\/produkto-kategorija\/contact-fittings-for-electrical-networks\/"},{"@type":"ListItem","position":4,"name":"Connectors","item":"https:\/\/www.gph.lt\/en\/produkto-kategorija\/contact-fittings-for-electrical-networks\/connectors\/"},{"@type":"ListItem","position":5,"name":"Pressed electrical cables","item":"https:\/\/www.gph.lt\/en\/produkto-kategorija\/contact-fittings-for-electrical-networks\/connectors\/pressed-electrical-cables\/"},{"@type":"ListItem","position":6,"name":"Compression tubes for lines without longitudinal load, DIN 46267, Part 1"}]},{"@type":"WebSite","@id":"https:\/\/www.gph.lt\/#website","url":"https:\/\/www.gph.lt\/","name":"GPH","description":"a Nexans company","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gph.lt\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product\/13193"}],"collection":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/comments?post=13193"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/media\/13194"}],"wp:attachment":[{"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/media?parent=13193"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product_cat?post=13193"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.gph.lt\/en\/wp-json\/wp\/v2\/product_tag?post=13193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}