Application: cable lugs for wet rooms and outdoor applications. For Al conductors according to DIN 48201 and Al cable strands according to VDE 0295.
Voltage: up to 36 kV;
Material: Al 99.5;
Surface:
ALU-F: uncoated;
ALU-F-V: electrochemically tin-plated (20 μm thick coating).
Name | Conductor cross-section, mm² (rm/sm)/se | Conductor diameter, mm (According to VDE 0295/According to DIN 48201/5) | Matrix code | D/d, mm | l/b, mm | Fixing screw M | Number of clamping points (mech./hidraul.) |
---|---|---|---|---|---|---|---|
16×8 ALU-F | 16/25 | 5.2-5.6/5.1 | 12 | 12.0/5.4 | 50/20 | 8.0 | 4/2 |
16×10 ALU-F | 16/25 | 5.2-5.6/5.1 | 12 | 12.0/5.4 | 50/25 | 10.0 | 4/2 |
25×8 ALU-F | 25/35 | 5.6-6.7/6.3 | 12 | 12.0/6.8 | 50/20 | 8.0 | 4/2 |
25×10 ALU-F | 25/35 | 5.6-6.7/6.3 | 12 | 12.0/6.8 | 50/25 | 10.0 | 4/2 |
25×12 ALU-F | 25/35 | 5.6-6.7/6.3 | 12 | 12.0/6.8 | 50/25 | 13.0 | 4/2 |
35×8 ALU-F | 35/50 | 6.6-7.8/7.5 | 14 | 14.0/8.0 | 62/25 | 8.0 | 5/2 |
35×10 ALU-F | 35/50 | 6.6-7.8/7.5 | 14 | 14.0/8.0 | 62/25 | 10.0 | 5/2 |
35×12 ALU-F | 35/50 | 6.6-7.8/7.5 | 14 | 14.0/8.0 | 62/25 | 13.0 | 5/2 |
50×8 ALU-F | 50/70 | 7.7-9.4/9.0 | 16 | 16.0/9.8 | 62/25 | 8.0 | 5/2 |
50×10 ALU-F | 50/70 | 7.7-9.4/9.0 | 16 | 16.0/9.8 | 62/25 | 10.0 | 5/2 |
50×12 ALU-F | 50/70 | 7.7-9.4/9.0 | 16 | 16.0/9.8 | 62/25 | 13.0 | 5/2 |
70×10 ALU-F | 70/95 | 9.3-11.0/10.5 | 18 | 18.5/11.2 | 72/25 | 10.5 | 6/3 |
70×12 ALU-F | 70/95 | 9.3-11.0/10.5 | 18 | 8.5/11.2 | 72/25 | 13.0 | 6/3 |
95×10 ALU-F | 95/120 | 11.0-12.4/12.5 | 22 | 22.0/13.2 | 78/25 | 10.0 | 6/3 |
95×12 ALU-F | 95/120 | 11.0-12.4/12.5 | 22 | 22.0/13.2 | 75/25 | 13.0 | 6/3 |
120×10 ALU-F | 120/150 | 12.5-13.8/14.0 | 22 | 23.0/14.7 | 84/30 | 10.0 | 6/3 |
120×12 ALU-F | 120/150 | 12.5-13.8/14.0 | 22 | 23.0/14.7 | 80/30 | 13.0 | 6/3 |
120×16 ALU-F | 120/150 | 12.5-13.8/14.0 | 22 | 23.0/14.7 | 80/30 | 17.0 | 6/3 |
150×10 ALU-F | 150/185 | 13.9-15.0/15.7 | 25 | 25.0/16.3 | 90/30 | 10.0 | 6/3 |
150×12 ALU-F | 15/185 | 13.9-15.0/15.7 | 25 | 25.0/16.3 | 90/30 | 13.0 | 6/3 |
150×16 ALU-F | 150/185 | 13.9-15.0/15.7 | 25 | 25.0/16.3 | 90/30 | 17.0 | 6/3 |
185×10 ALU-F | 185/240 | 15.5-16.8/17.5 | 28 | 28.5/18.3 | 91/30 | 10.0 | 6/3 |
185×12 ALU-F | 185/240 | 15.5-16.8/17.5 | 28 | 28.5/18.3 | 91/30 | 13.0 | 6/3 |
185×16 ALU-F | 185/240 | 15.5-16.8/17.5 | 28 | 28.5/18.3 | 91/30 | 17.0 | 6/3 |
185×20 ALU-F | 185/240 | 15.5-16.8/17.5 | 28 | 28.5/18.3 | 91/38 | 21.0 | 6/3 |
240×10 ALU-F | 240/300 | 17.8-19.2/20.3 | 32 | 32.0/21.0 | 103/38 | 10.0 | 8/3 |
240×12 ALU-F | 240/300 | 17.8-19.2/20.3 | 32 | 32.0/21.0 | 103/38 | 13.0 | 8/3 |
240×16 ALU-F | 240/300 | 17.8-19.2/20.3 | 32 | 32.0/21.0 | 103/38 | 17.0 | 8/3 |
240×20 ALU-F | 240/300 | 17.8-19.2/20.3 | 32 | 32.0/21.0 | 103/38 | 21.0 | 8/3 |
300×12 ALU-F | 300 | 20.0-21.6/22.5 | 34 | 34.0/23.3 | 103/38 | 13.0 | 8/3 |
300×16 ALU-F | 300 | 20.0-21.6/22.5 | 34 | 34.0/23.3 | 103/38 | 17.0 | 8/3 |
400×12 ALU-F | 400 | 22.9-24.6 | 38 | 38.5/26.0 | 116/38 | 13.0 | -/3 |
500×12 ALU-F | 500 | 25.7-27.6 | 44 | 44.0/29.0 | 122/44 | 13.0 | -/4 |
500×16 ALU-F | 500 | 25.7-27.6 | 44 | 44.0/29.0 | 122/44 | 17.0 | -/4 |
Please enquire further about other nozzle sizes and ALU-F-V (tin-plated) nozzles. Cable lugs are filled with special contact paste and hermetically sealed in plastic.
Designations used: rm-round multicore conductor; sm-sector multicore conductor; re-conductor single-wire round monolith; se-conductor single-wire sector monolith.