Purpose:
For branch connection without de-energizing overhead cable lines under voltage. For use up to 1 kV.
Voltage: up to 1 kV;
Material:
Housing: glass fiber, armored plastic;
contact plates: copper alloy, bleached;
plates and screws: hot-dip galvanized steel.
Mandatory tightening torque M 8:15 Nm.
Name | Main conductor cross-section, mm² | Branch conductor cross-section, mm² | Screw size (diameter/length) | L, mm | B, mm | Number of Bolts | Rotational torque, Nm |
---|---|---|---|---|---|---|---|
IS 5005 | 25-70 | 6.0-35 | M 8×55 | 33 | 38 | 1 | 15-22 |
IS 5022 | 25-95 | 1.5-6.0 | M 8×45 | 36 | 26 | 1 | 12-15 |
IS 5002 | 25-95 | 10-50 | M 8×68 | 54 | 52 | 2 | 15 |
IS 5008 | 50-150 | 10-95 | M 8×68 | 54 | 56 | 2 | 15 |
IS 5025 | 25-70 | 6.0-35 | M 8×55 | 33 | 38 | 1 | 15-22 |
IS 5010 | 50-150 | 10-95 | M 8×68 | 54 | 56 | 2 | 15 |
IS 5020 | 35-95 | 6-70 | M 10×70 | 50 | 50 | 1 | 22 |
*Other sizes on request